NEC · CALCULATORS

Electrical calculators

19 calculators across branch circuits, feeders, services, motors, conduit fill, and voltage drop. All browser-based, all show their work.

VIEW IN LAB CATALOG
FAULT CURRENTREADY

SCCR / AIC Fault Current Compliance Checker

Check assembly SCCR and device AIC ratings against available fault current — with a sensitivity analysis, equipment comparison explorer, step-by-step calculation trace, current-limiting fuse impact, and NEC code-logic walkthrough.

NEC 110.9 / 110.10AIC vs SCCRCURRENT-LIMITING MODELNEC 2017 / 2020 / 2026
INTERMEDIATEVIEW LAB
NEC CALCULATORSREADY

Box Fill Calculator

Calculate NEC 314.16 box fill volume by entering conductors, looped conductors, internal cable clamps, device yokes, and equipment grounding conductors — with a box cross-section visualization, category breakdown, five preset scenarios, and a knowledge-check quiz.

NEC • 314.16(A)/(B)/(C)5 FILL CATEGORIES5 PRESET SCENARIOSBOX CROSS-SECTION VIZ
BEGINNERVIEW LAB
NEC CALCULATORSREADY

Commercial Load Build-Up Calculator

Build a commercial service load from the ground up across 13 occupancy types — stacking general lighting, receptacle, motor, HVAC, sign, and special loads with NEC Article 220 demand factors applied per category, with a load stack chart, what-if scenarios, load balance analysis, and calculation trace.

NEC • ART. 22013 OCCUPANCY TYPESMOTOR + SIGN LOADSWHAT-IF SCENARIOS
INTERMEDIATEVIEW LAB
NEC CALCULATORSREADY

Conductor Ampacity & Wire Sizing Calculator

Size conductors under NEC Article 310 — pick load, material, insulation, and terminal rating, then apply ambient temperature correction and bundling adjustment factors in the correct code order to land on a compliant AWG/kcmil size.

NEC • 310.16110.14(C) TERMINAL CAPAMBIENT + BUNDLINGCOPPER / ALUMINUM
INTERMEDIATEVIEW LAB
NEC CALCULATORSREADY

Conductor Derating & Adjustment Explorer

Apply temperature correction and bundling adjustment factors to conductor ampacity in the correct NEC order — with table selection (310.16 vs. 310.17), neutral CCC determination, terminal temperature cap, and parametric charts showing how each factor shifts the final allowable ampacity.

NEC • 310.15(B)/(C)310.16 + 310.17TEMP CORR × BUNDLE ADJPARAMETRIC CHARTS
INTERMEDIATEVIEW LAB
NEC CALCULATORSREADY

Conduit Fill Calculator

Add conductors by wire type, AWG, and insulation to any of seven raceway types — get live NEC Chapter 9 fill percentage, pass/fail status, and auto-select the smallest compliant conduit size, with a step-by-step trace and design challenge mode.

NEC • CH. 97 RACEWAY TYPES5 INSULATION TYPESAUTO CONDUIT SIZING
BEGINNERVIEW LAB
NEC CALCULATORSREADY

Continuous Load Sizing Basis Calculator

Enter continuous and noncontinuous load amperes for a branch circuit, feeder, or service and get the NEC sizing basis — with the 125% multiplier applied correctly, the 100%-rated assembly exception explained as a listing condition, and edition-specific notes for 2017, 2020, and 2026.

NEC • 210.19 / 215.2 / 230.42125% RULE100%-RATED EXCEPTION2017 / 2020 / 2026
BEGINNERVIEW LAB
NEC CALCULATORSREADY

Dwelling Unit Load Calculator

Calculate dwelling service load using all three NEC Article 220 methods — Standard (220.82 Part III), Optional (220.82), and Existing Dwelling (220.83) — with side-by-side comparison, service size ladder, and five preset scenarios including an undersized service case.

NEC • ART. 2203 CALCULATION METHODSSIDE-BY-SIDE COMPARE100–400 A SERVICE LADDER
BEGINNERVIEW LAB
NEC CALCULATORSREADY

General Lighting & Receptacle Branch-Circuit Calculator

Size general lighting and receptacle branch circuits under NEC Articles 210 and 220 — with occupancy VA/ft² lookup, custom VA entry, continuous-load factor, receptacle and dedicated-load configuration, and a circuit designer with self-test mode.

NEC • ART. 210 / 220VA/FT² TABLE LOOKUP5 OCCUPANCY PRESETS2017 / 2020 / 2026
BEGINNERVIEW LAB
NEC CALCULATORSREADY

Grounding Electrode Conductor (GEC) Sizing Calculator

Size the grounding electrode conductor from NEC Table 250.66 for service entrances and separately derived systems — with electrode-type sub-rules (250.66(A/B/C)), parallel conductor sets, material selection, and six preset configurations.

NEC • 250.6614 AWG – 2000 kcmil3 ELECTRODE SUB-RULES6 PRESET CONFIGS
INTERMEDIATEVIEW LAB
NEC CALCULATORSREADY

Equipment Grounding Conductor (EGC) Sizing Calculator

Size equipment grounding conductors from NEC Table 250.122 — with upsizing for derated phase conductors, parallel feeder configurations, raceway-as-EGC path evaluation, and a visual EGC vs. GEC distinction diagram.

NEC • 250.12215 A – 6000 A OCPDPARALLEL + UPSIZE LOGICEGC vs GEC DIAGRAM
INTERMEDIATEVIEW LAB
NEC CALCULATORSREADY

HVAC & Refrigeration MCA / MOCP Interpreter

Read HVAC and refrigeration equipment nameplates correctly under NEC Article 440 — enter marked MCA and MOCP values, select your conductor and OCPD, and get an immediate pass/fail against both nameplate requirements with a live circuit visualizer and a side-by-side Article 440 vs. 430 comparison.

NEC • ART. 440MCA / MOCP NAMEPLATE6 PRESET SCENARIOS430 vs 440 COMPARISON
INTERMEDIATEVIEW LAB
NEC CALCULATORSREADY

Motor Branch-Circuit Conductor & OCPD Study Tool

Size branch-circuit conductors, overload protection, and OCPD for single-motor circuits under NEC Article 430 — with a live one-line diagram, motor starting current simulation, illustrative TCC, Table 430.52(C)(1) multiplier matrix, copper-vs-aluminum comparison, and self-test mode.

NEC • ART. 430FLC TABLE LOOKUPSTARTING CURRENT SIM430.52 MATRIX
INTERMEDIATEVIEW LAB
NEC CALCULATORSREADY

Multiple Motor Feeder & Service Calculator

Add multiple motors and optional non-motor loads to size a feeder conductor and feeder OCPD under NEC Article 430 — two distinct calculations (430.24 and 430.62) with FLC table lookups, a step-by-step trace, and six common-mistake guards built in.

NEC • 430.24NEC • 430.62FLC TABLES 430.247–.250FEEDER + OCPD
ADVANCEDVIEW LAB
NEC CALCULATORSREADY

OCPD Sizing Calculator

Size overcurrent protective devices for general, continuous, and motor branch circuits under NEC 240.4 and 430.52 — with device-type selector, next-standard-size logic, conductor protection check, 100%-rated assembly exception, and seven preset scenarios illustrating common sizing traps.

NEC • 240.4 / 430.527 PRESET TRAPS240.4(B)/(C)/(D) LOGICNEXT STANDARD SIZE
INTERMEDIATEVIEW LAB
NEC CALCULATORSREADY

Panelboard & Feeder Load Calculation

Build a multi-category panelboard or feeder load schedule with NEC Article 220 demand factors applied per category — general lighting, receptacles, kitchen, motors, HVAC, and more — then evaluate feeder conductor sizing and bus utilization.

NEC • ART. 22015 LOAD CATEGORIESNONCOINCIDENT HVACBUS UTILIZATION CHECK
INTERMEDIATEVIEW LAB
NEC CALCULATORSREADY

Service & Feeder Conductor Sizing Calculator

Size service entrance and feeder conductors under NEC Articles 215 and 230 — with continuous-load factor, ambient and bundling correction, material and terminal temperature cap, voltage drop, and a design challenge mode.

NEC • ART. 215 / 23090°C LOOKUP → TERMINAL CAP6 PRESET SCENARIOSDESIGN CHALLENGE MODE
INTERMEDIATEVIEW LAB
NEC CALCULATORSREADY

Voltage Drop Calculator & Explorer

Calculate AC voltage drop for single- and three-phase circuits across five voltages and two conductor materials — with live parametric charts (drop vs. length, vs. current, vs. temperature), a copper-vs-aluminum comparison, conductor explorer, six quick presets, and a scenario lab.

120–600 V · 1φ / 3φNEC CH. 9 TABLES6 PARAMETRIC CHARTSCu vs Al COMPARISON
BEGINNERVIEW LAB
NEC CALCULATORSREADY

EV Charger Branch, Feeder & Service Calculator

Size branch circuits, feeders, and service entrances for EVSE installations under NEC 625 — supporting Level 1, Level 2, and DC Fast charging with demand factor application and multi-unit feeder aggregation.

NEC • ART. 625L1 / L2 / DC FASTNEC 2017 / 2020FEEDER AGGREGATION
INTERMEDIATEVIEW LAB