LAB CATALOG

Interactive labs, calculators & simulators

49 browser-based tools across 11 disciplines. Filter by category, difficulty, audience, or status.

19 RESULTS
NEC CALCULATORSREADY

Box Fill Calculator

Calculate NEC 314.16 box fill volume by entering conductors, looped conductors, internal cable clamps, device yokes, and equipment grounding conductors — with a box cross-section visualization, category breakdown, five preset scenarios, and a knowledge-check quiz.

NEC • 314.16(A)/(B)/(C)5 FILL CATEGORIES5 PRESET SCENARIOSBOX CROSS-SECTION VIZ
BEGINNERVIEW LAB
NEC CALCULATORSREADY

Commercial Load Build-Up Calculator

Build a commercial service load from the ground up across 13 occupancy types — stacking general lighting, receptacle, motor, HVAC, sign, and special loads with NEC Article 220 demand factors applied per category, with a load stack chart, what-if scenarios, load balance analysis, and calculation trace.

NEC • ART. 22013 OCCUPANCY TYPESMOTOR + SIGN LOADSWHAT-IF SCENARIOS
INTERMEDIATEVIEW LAB
NEC CALCULATORSREADY

Conductor Ampacity & Wire Sizing Calculator

Size conductors under NEC Article 310 — pick load, material, insulation, and terminal rating, then apply ambient temperature correction and bundling adjustment factors in the correct code order to land on a compliant AWG/kcmil size.

NEC • 310.16110.14(C) TERMINAL CAPAMBIENT + BUNDLINGCOPPER / ALUMINUM
INTERMEDIATEVIEW LAB
NEC CALCULATORSREADY

Conductor Derating & Adjustment Explorer

Apply temperature correction and bundling adjustment factors to conductor ampacity in the correct NEC order — with table selection (310.16 vs. 310.17), neutral CCC determination, terminal temperature cap, and parametric charts showing how each factor shifts the final allowable ampacity.

NEC • 310.15(B)/(C)310.16 + 310.17TEMP CORR × BUNDLE ADJPARAMETRIC CHARTS
INTERMEDIATEVIEW LAB
NEC CALCULATORSREADY

Conduit Fill Calculator

Add conductors by wire type, AWG, and insulation to any of seven raceway types — get live NEC Chapter 9 fill percentage, pass/fail status, and auto-select the smallest compliant conduit size, with a step-by-step trace and design challenge mode.

NEC • CH. 97 RACEWAY TYPES5 INSULATION TYPESAUTO CONDUIT SIZING
BEGINNERVIEW LAB
NEC CALCULATORSREADY

Continuous Load Sizing Basis Calculator

Enter continuous and noncontinuous load amperes for a branch circuit, feeder, or service and get the NEC sizing basis — with the 125% multiplier applied correctly, the 100%-rated assembly exception explained as a listing condition, and edition-specific notes for 2017, 2020, and 2026.

NEC • 210.19 / 215.2 / 230.42125% RULE100%-RATED EXCEPTION2017 / 2020 / 2026
BEGINNERVIEW LAB
NEC CALCULATORSREADY

Dwelling Unit Load Calculator

Calculate dwelling service load using all three NEC Article 220 methods — Standard (220.82 Part III), Optional (220.82), and Existing Dwelling (220.83) — with side-by-side comparison, service size ladder, and five preset scenarios including an undersized service case.

NEC • ART. 2203 CALCULATION METHODSSIDE-BY-SIDE COMPARE100–400 A SERVICE LADDER
BEGINNERVIEW LAB
NEC CALCULATORSREADY

Equipment Grounding Conductor (EGC) Sizing Calculator

Size equipment grounding conductors from NEC Table 250.122 — with upsizing for derated phase conductors, parallel feeder configurations, raceway-as-EGC path evaluation, and a visual EGC vs. GEC distinction diagram.

NEC • 250.12215 A – 6000 A OCPDPARALLEL + UPSIZE LOGICEGC vs GEC DIAGRAM
INTERMEDIATEVIEW LAB
NEC CALCULATORSREADY

EV Charger Branch, Feeder & Service Calculator

Size branch circuits, feeders, and service entrances for EVSE installations under NEC 625 — supporting Level 1, Level 2, and DC Fast charging with demand factor application and multi-unit feeder aggregation.

NEC • ART. 625L1 / L2 / DC FASTNEC 2017 / 2020FEEDER AGGREGATION
INTERMEDIATEVIEW LAB
NEC CALCULATORSREADY

General Lighting & Receptacle Branch-Circuit Calculator

Size general lighting and receptacle branch circuits under NEC Articles 210 and 220 — with occupancy VA/ft² lookup, custom VA entry, continuous-load factor, receptacle and dedicated-load configuration, and a circuit designer with self-test mode.

NEC • ART. 210 / 220VA/FT² TABLE LOOKUP5 OCCUPANCY PRESETS2017 / 2020 / 2026
BEGINNERVIEW LAB
NEC CALCULATORSREADY

Grounding Electrode Conductor (GEC) Sizing Calculator

Size the grounding electrode conductor from NEC Table 250.66 for service entrances and separately derived systems — with electrode-type sub-rules (250.66(A/B/C)), parallel conductor sets, material selection, and six preset configurations.

NEC • 250.6614 AWG – 2000 kcmil3 ELECTRODE SUB-RULES6 PRESET CONFIGS
INTERMEDIATEVIEW LAB
NEC CALCULATORSREADY

HVAC & Refrigeration MCA / MOCP Interpreter

Read HVAC and refrigeration equipment nameplates correctly under NEC Article 440 — enter marked MCA and MOCP values, select your conductor and OCPD, and get an immediate pass/fail against both nameplate requirements with a live circuit visualizer and a side-by-side Article 440 vs. 430 comparison.

NEC • ART. 440MCA / MOCP NAMEPLATE6 PRESET SCENARIOS430 vs 440 COMPARISON
INTERMEDIATEVIEW LAB
NEC CALCULATORSREADY

Motor Branch-Circuit Conductor & OCPD Study Tool

Size branch-circuit conductors, overload protection, and OCPD for single-motor circuits under NEC Article 430 — with a live one-line diagram, motor starting current simulation, illustrative TCC, Table 430.52(C)(1) multiplier matrix, copper-vs-aluminum comparison, and self-test mode.

NEC • ART. 430FLC TABLE LOOKUPSTARTING CURRENT SIM430.52 MATRIX
INTERMEDIATEVIEW LAB
NEC CALCULATORSREADY

Multiple Motor Feeder & Service Calculator

Add multiple motors and optional non-motor loads to size a feeder conductor and feeder OCPD under NEC Article 430 — two distinct calculations (430.24 and 430.62) with FLC table lookups, a step-by-step trace, and six common-mistake guards built in.

NEC • 430.24NEC • 430.62FLC TABLES 430.247–.250FEEDER + OCPD
ADVANCEDVIEW LAB
NEC CALCULATORSREADY

OCPD Sizing Calculator

Size overcurrent protective devices for general, continuous, and motor branch circuits under NEC 240.4 and 430.52 — with device-type selector, next-standard-size logic, conductor protection check, 100%-rated assembly exception, and seven preset scenarios illustrating common sizing traps.

NEC • 240.4 / 430.527 PRESET TRAPS240.4(B)/(C)/(D) LOGICNEXT STANDARD SIZE
INTERMEDIATEVIEW LAB
NEC CALCULATORSREADY

Panelboard & Feeder Load Calculation

Build a multi-category panelboard or feeder load schedule with NEC Article 220 demand factors applied per category — general lighting, receptacles, kitchen, motors, HVAC, and more — then evaluate feeder conductor sizing and bus utilization.

NEC • ART. 22015 LOAD CATEGORIESNONCOINCIDENT HVACBUS UTILIZATION CHECK
INTERMEDIATEVIEW LAB
FAULT CURRENTREADY

SCCR / AIC Fault Current Compliance Checker

Check assembly SCCR and device AIC ratings against available fault current — with a sensitivity analysis, equipment comparison explorer, step-by-step calculation trace, current-limiting fuse impact, and NEC code-logic walkthrough.

NEC 110.9 / 110.10AIC vs SCCRCURRENT-LIMITING MODELNEC 2017 / 2020 / 2026
INTERMEDIATEVIEW LAB
NEC CALCULATORSREADY

Service & Feeder Conductor Sizing Calculator

Size service entrance and feeder conductors under NEC Articles 215 and 230 — with continuous-load factor, ambient and bundling correction, material and terminal temperature cap, voltage drop, and a design challenge mode.

NEC • ART. 215 / 23090°C LOOKUP → TERMINAL CAP6 PRESET SCENARIOSDESIGN CHALLENGE MODE
INTERMEDIATEVIEW LAB
NEC CALCULATORSREADY

Voltage Drop Calculator & Explorer

Calculate AC voltage drop for single- and three-phase circuits across five voltages and two conductor materials — with live parametric charts (drop vs. length, vs. current, vs. temperature), a copper-vs-aluminum comparison, conductor explorer, six quick presets, and a scenario lab.

120–600 V · 1φ / 3φNEC CH. 9 TABLES6 PARAMETRIC CHARTSCu vs Al COMPARISON
BEGINNERVIEW LAB