LAB CATALOG

Interactive labs, calculators & simulators

49 browser-based tools across 11 disciplines. Filter by category, difficulty, audience, or status.

15 RESULTS
ARC FLASHREADY

Arc Flash Concept Simulator

Explore how voltage, available fault current, working distance, clearing time, equipment configuration, and protection features influence conceptual incident energy and arc-flash boundary behavior.

CONCEPTUAL MODELNOT IEEE 15845 SCENARIOS208 V – 15 kV
INTERMEDIATEVIEW LAB
PROTECTION & RELAYSIN REVIEW

CT / PT and Relay Measurement Simulator

Trace how current and voltage transformers scale primary quantities for relay inputs — then inject load, fault, and ground fault currents to see how overcurrent, differential, and directional relays respond in real time.

CT · PT SCALING5 RELAY FUNCTIONS8 FAULT SCENARIOSSATURATION MODEL
ADVANCEDVIEW LAB
FAULT CURRENTREADY

Fault Current & Short-Circuit Simulator

Model three-phase, SLG, LL, and DLG faults across a four-bus radial system using the per-unit method — with configurable source impedance, transformer, cable, and relay — and a clear statement of what a code-grade study includes that this educational tool does not.

4 FAULT TYPES4 BUS LOCATIONSPER-UNIT METHODX/R ASYMMETRIC MODEL
ADVANCEDVIEW LAB
POWER SYSTEMS FUNDAMENTALSREADY

Generator, ATS & Emergency Power Sequence Simulator

Step through the full utility-loss-to-generator-transfer sequence — start delay, warm-up, ATS transfer, re-transfer, cooldown — with configurable timing parameters, a live one-line diagram, state machine view, and event timeline.

FULL ATS SEQUENCELIVE ONE-LINESTATE MACHINE VIEWCONFIGURABLE TIMING
INTERMEDIATEVIEW LAB
GROUNDING & BONDINGREADY

Grounding & Bonding System Visualizer

Visualize grounding and bonding current paths across service entrances, separately derived sources, generators, and UPS systems — with fault injection showing how grounding method and bonding connections control fault-current return paths.

NEC • ART. 2504 SOURCE TYPES3 GROUNDING METHODSFAULT PATH ANIMATION
BEGINNERVIEW LAB
POWER QUALITYREADY

Harmonics & Waveform Distortion Lab

Build distorted waveforms by mixing harmonic orders 3 through 13, measure THD and K-factor in real time, and explore how VFDs, rectifiers, LED drivers, and office electronics each create distinct harmonic signatures.

FOURIER • H3–H13IEEE 519 VALIDATIONK-FACTOR MODELLIVE THD CALC
INTERMEDIATEVIEW LAB
MOTORSREADY

Motor Starting Simulator

Compare Across-the-Line, Reduced Voltage Auto-Transformer, Soft Starter, and VFD starting methods on live current, speed, and torque curves — with configurable HP, inertia, NEMA design class, and voltage from 208 V to 4160 V.

4 STARTING METHODS1–500 HP · 208–4160 VNEMA A / C / DLIVE TORQUE CURVES
INTERMEDIATEVIEW LAB
POWER SYSTEMS FUNDAMENTALSIN REVIEW

One-Line Diagram Builder & Explorer

Build, edit, and explore single-line diagrams using standard power system symbols — with automatic energized-path tracing, load aggregation, connection mapping, and five preset system topologies.

5 PRESET TOPOLOGIESPATH TRACINGLOAD AGGREGATIONSTANDARD SYMBOLS
INTERMEDIATEVIEW LAB
POWER QUALITYREADY

Power Factor Correction Simulator

Add capacitor bank kVAR to a lagging-power-factor load and watch the power triangle, current, and illustrative utility penalty model update — with six real-world load scenarios and an over-correction demonstration.

POWER TRIANGLE LIVE120 V – 13.8 kV6 LOAD SCENARIOSOVER-CORRECTION MODEL
INTERMEDIATEVIEW LAB
POWER SYSTEMS FUNDAMENTALSREADY

Power System Simulator

Model a three-phase or single-phase power system — configure source voltage, a transformer, and multiple loads, apply power factor correction, and see live phasor diagrams, voltage and current waveforms, and system metrics update in real time.

3-PHASE / 1-PHASEWYE / DELTALIVE PHASOR + WAVEFORMPF CORRECTION MODEL
INTERMEDIATEVIEW LAB
TRANSFORMERSREADY

Power Transformer Simulator

Model a power transformer from 25 kVA to 10 MVA — adjust loading, impedance, power factor, tap position, and ambient temperature, then explore efficiency curves, thermal loading, voltage regulation, and fault behavior.

25 kVA – 10 MVAEFFICIENCY CURVETHERMAL MODELTAP CHANGER
INTERMEDIATEVIEW LAB
PROTECTION & RELAYSREADY

Protection Zone & Relay Scheme Explorer

Explore protection zones, relay responsibility areas, and scheme behavior across four system topologies — then drive fault scenarios including feeder faults, bus faults, transformer internal faults, backup operation, and breaker failure.

4 SYSTEM TOPOLOGIES6 FAULT SCENARIOSSETTINGS LABZONE VISUALIZATION
ADVANCEDVIEW LAB
POWER SYSTEMS FUNDAMENTALSREADY

Substation & Switchgear Bus Configuration Explorer

Compare Single Bus, Double-Ended, Sectionalized, and Alternate Source topologies under normal operation and fault conditions — evaluate reliability metrics, model transfer types, and walk through six sequenced operations scenarios.

4 BUS TOPOLOGIES6 OPERATIONS SCENARIOSRELIABILITY METRICS4 TRANSFER TYPES
INTERMEDIATEVIEW LAB
POWER SYSTEMS FUNDAMENTALSREADY

Symmetrical Components & Fault Visualizer

Decompose unbalanced three-phase systems into positive, negative, and zero-sequence networks — then drive fault current through them and see every sequence quantity update in real time.

SEQUENCE NETWORK SOLVER4 FAULT TYPES3 GROUNDING MODES480 V – 138 kV
ADVANCEDVIEW LAB
TRANSFORMERSREADY

Transformer Vector Group & Polarity Visualizer

Visualize Delta-Wye, Wye-Delta, Delta-Delta, and Wye-Wye transformer connections with live phasor diagrams showing primary and secondary voltage relationships, phase shift, and polarity for balanced, unbalanced, and single-phase conditions.

Dy / Yd / Dd / YyCLOCK-HOUR SHIFTLIVE PHASOR DIAGRAMDOT CONVENTION
INTERMEDIATEVIEW LAB