ARC FLASH
Availability: AVAILABLE

Arc Flash Concept Simulator

Explain how incident energy is influenced by available fault current, clearing time, working distance, and equipment configuration.

SIMULATOR · 15–35 MIN · ENGINEER
  • NFPA 70E
  • IEEE 1584
  • ARC FLASH
INTERMEDIATEVIEW LAB
PROTECTION & RELAYS
Availability: PREVIEW

CT / PT and Relay Measurement Simulator

Explain how CT ratio and burden affect secondary current accuracy and relay input.

SIMULATOR · 25–45 MIN · ENGINEER
  • IEEE
  • NETA ATS
  • NETA MTS
ADVANCEDVIEW LAB
FAULT CURRENT
Availability: AVAILABLE

Fault Current & Short-Circuit Simulator

Convert system impedances to a common per-unit base and compute total impedance from source to fault location.

SIMULATOR · 20–40 MIN · ENGINEER
  • IEEE
  • IEC 60909
  • SHORT CIRCUIT
ADVANCEDVIEW LAB
POWER SYSTEMS FUNDAMENTALS
Availability: AVAILABLE

Generator, ATS & Emergency Power Sequence Simulator

List the sequence of states from utility loss to stable generator supply and identify timing requirements for each.

SIMULATOR · 15–30 MIN · ENGINEER
  • GENERATOR
  • ATS
  • EMERGENCY POWER
INTERMEDIATEVIEW LAB
GROUNDING & BONDING
Availability: AVAILABLE

Grounding & Bonding System Visualizer

Distinguish between grounding (earth connection) and bonding (equipotential connection) as defined by NEC Article 250.

SIMULATOR · 15–30 MIN · ENGINEER
  • NEC
  • GROUNDING
  • BONDING
BEGINNERVIEW LAB
POWER QUALITY
Availability: AVAILABLE

Harmonics & Waveform Distortion Lab

Explain Fourier decomposition and how any periodic waveform can be expressed as a sum of harmonic components.

SIMULATOR · 20–35 MIN · ENGINEER
  • IEEE
  • HARMONICS
  • THD
INTERMEDIATEVIEW LAB
MOTORS
Availability: AVAILABLE

Motor Starting Simulator

Compare inrush current magnitude and duration for DOL, reduced voltage, soft starter, and VFD starting methods.

SIMULATOR · 20–35 MIN · ENGINEER
  • IEEE
  • MOTOR STARTING
  • DOL
INTERMEDIATEVIEW LAB
POWER SYSTEMS FUNDAMENTALS
Availability: PREVIEW

One-Line Diagram Builder & Explorer

Place and connect standard one-line diagram symbols for sources, transformers, breakers, buses, and loads.

DIAGRAM BUILDER · 20–40 MIN · ENGINEER
  • ONE-LINE DIAGRAM
  • SINGLE-LINE DIAGRAM
  • SLD
INTERMEDIATEVIEW LAB
POWER QUALITY
Availability: AVAILABLE

Power Factor Correction Simulator

Draw and label the power triangle with real (kW), reactive (kVAR), and apparent (kVA) power components.

SIMULATOR · 15–25 MIN · ENGINEER
  • IEEE
  • POWER FACTOR
  • KVAR
INTERMEDIATEVIEW LAB
POWER SYSTEMS FUNDAMENTALS
Availability: AVAILABLE

Power System Simulator

Calculate line-to-neutral and line-to-line voltages for both Wye and Delta connections given source voltage.

DIAGRAM BUILDER · 15–30 MIN · ENGINEER
  • THREE-PHASE POWER
  • SINGLE-PHASE
  • PHASOR DIAGRAM
INTERMEDIATEVIEW LAB
TRANSFORMERS
Availability: AVAILABLE

Power Transformer Simulator

Explain the two components of transformer losses — core (no-load) losses and copper (load) losses — and identify at what load level efficiency is m…

SIMULATOR · 20–35 MIN · ENGINEER
  • IEEE
  • NETA ATS
  • TRANSFORMER
INTERMEDIATEVIEW LAB
PROTECTION & RELAYS
Availability: AVAILABLE

Protection Zone & Relay Scheme Explorer

Draw and describe the protection zone boundaries for feeder, transformer, and bus protection in a simple substation.

SIMULATOR · 25–45 MIN · ENGINEER
  • IEEE
  • PROTECTION RELAY
  • PROTECTION ZONE
ADVANCEDVIEW LAB
POWER SYSTEMS FUNDAMENTALS
Availability: AVAILABLE

Substation & Switchgear Bus Configuration Explorer

Describe the key differences between single bus, double-ended, sectionalized bus, and alternate source configurations in terms of redundancy and sw…

SIMULATOR · 25–45 MIN · ENGINEER
  • IEEE
  • SUBSTATION
  • BUS CONFIGURATION
INTERMEDIATEVIEW LAB
POWER SYSTEMS FUNDAMENTALS
Availability: AVAILABLE

Symmetrical Components & Fault Visualizer

Explain why any unbalanced phasor set can be decomposed into three balanced sequence sets.

DIAGRAM BUILDER · 20–45 MIN · ENGINEER
  • IEEE
  • IEC 60909
  • SYMMETRICAL COMPONENTS
ADVANCEDVIEW LAB
TRANSFORMERS
Availability: AVAILABLE

Transformer Vector Group & Polarity Visualizer

Interpret an IEC vector group designation (e.g., Dyn11, YNd1) and identify the winding connection and phase shift it encodes.

DIAGRAM BUILDER · 15–25 MIN · ENGINEER
  • IEEE
  • DYN11
  • YND1
INTERMEDIATEVIEW LAB