NEC Calculation Practice
Structured practice moving from a single branch circuit to a complete service calculation. Every module works from computed results with citations to the applicable article — never reproduced tables.
- LEVEL
- Intermediate
- TOTAL TIME
- 2 h 50 min · 5 modules
- AUDIENCE
- Student, Technician, Engineer, Contractor
- VERSION
- v2.0 · Published
Progress is saved on this device. Sign in to sync it privately to your account and continue on another device.
Module timeline
Branch circuits and continuous loads
Guided scenario 30 minAssemble a lighting and receptacle branch circuit and apply continuous-load treatment.
Lab: General Lighting & Receptacle Branch-Circuit CalculatorCompletes on: prediction recorded, lab opened, guided scenario steps confirmed, knowledge check submitted, reflection confirmedOpen moduleDwelling unit load calculation
Guided scenario 40 minComplete a standard-method dwelling calculation and explain each demand factor applied.
Lab: Dwelling Unit Load CalculatorCompletes on: lab opened, guided scenario steps confirmed, knowledge check submitted, reflection confirmedOpen moduleCommercial load buildup
Guided scenario 40 minBuild a commercial load with demand factors applied in the correct sequence.
Lab: Commercial Load Build-Up CalculatorCompletes on: lab opened, guided scenario steps confirmed, knowledge check submitted, reflection confirmedOpen moduleService and feeder sizing
Guided scenario 35 minSize a service or feeder from a calculated load and justify conductor and OCPD selection.
Lab: Service & Feeder Conductor Sizing CalculatorCompletes on: lab opened, guided scenario steps confirmed, knowledge check submitted, reflection confirmedOpen moduleVoltage drop check
Guided scenario 25 minValidate the sized feeder against voltage drop and revise where drop governs.
Lab: Voltage Drop Calculator & ExplorerCompletes on: lab opened, guided scenario steps confirmed, knowledge check submitted, reflection confirmedOpen module
What you will be able to do
- Build a branch circuit load and apply continuous-load treatment correctly
- Perform a dwelling unit load calculation using the standard method
- Build up a commercial load with demand factors applied in the right order
- Size a service or feeder and defend each input
- Check the result against voltage drop before committing to a size
Prerequisites
- Electrical Foundations, or equivalent working knowledge of Ohm's law and three-phase basics
What counts as complete
All five modules marked complete, each requiring the guided scenario steps, the knowledge check, and the reflection prompt.
Opening a lab never marks a module complete on its own.
Recommended next path
Power Systems AnalysisOne-lines, fault current, sequence networks, and bus arrangements.