PROTECTION & RELAYSREADY

Breaker Trip Unit Simulator

Set LSIG trip unit parameters on a live TCC and see how Long-Time, Short-Time, Instantaneous, and Ground-Fault regions respond to load and fault current — with six presets, five industry-specific Design Lab scenarios, a side-by-side Compare tab, and an Event Simulator.

LSIG TRIP UNIT4 FRAME SIZESDESIGN LAB SCENARIOSLIVE TCC PLOT
INTERMEDIATEVIEW LAB
PROTECTION & RELAYSIN REVIEW

CT / PT and Relay Measurement Simulator

Trace how current and voltage transformers scale primary quantities for relay inputs — then inject load, fault, and ground fault currents to see how overcurrent, differential, and directional relays respond in real time.

CT · PT SCALING5 RELAY FUNCTIONS8 FAULT SCENARIOSSATURATION MODEL
ADVANCEDVIEW LAB
PROTECTION & RELAYSREADY

Differential Protection Simulator

Simulate 87T transformer and 87B bus differential protection — adjust slope, pickup, and harmonic restraint, then drive internal faults, external faults, and inrush to see the operate/restraint characteristic respond in real time.

87T / 87B DIFFERENTIALSLOPE + HARMONIC RESTRAINOPERATE vs RESTRAINTLIVE WAVEFORMS
ADVANCEDVIEW LAB
PROTECTION & RELAYSREADY

Protection Zone & Relay Scheme Explorer

Explore protection zones, relay responsibility areas, and scheme behavior across four system topologies — then drive fault scenarios including feeder faults, bus faults, transformer internal faults, backup operation, and breaker failure.

4 SYSTEM TOPOLOGIES6 FAULT SCENARIOSSETTINGS LABZONE VISUALIZATION
ADVANCEDVIEW LAB
PROTECTION & RELAYSREADY

Protective Relay Coordination / TCC Visualizer

Plot upstream and downstream IEC IDMT relay, breaker, and fuse curves on a live TCC — then verify CTI margin, inject fault current, and step through the trip sequence using six preset coordination scenarios.

IEC IDMT CURVES6 PRESET SCENARIOSCTI MARGIN CHECKTRIP SEQUENCE ANIMATOR
ADVANCEDVIEW LAB
PROTECTION & RELAYSREADY

Protective Relay Test Record

A complete NETA-compliant protective relay test record for acceptance, maintenance, and commissioning — with dynamic relay element entry, calibrated test equipment logging, visual inspection checklist, deficiency tracking, safety controls documentation, and print-to-PDF output.

NETA ATS-2025 / MTS-2023NIST CAL TRACEABILITYJSON EXPORT / IMPORTPRINT TO PDF
FIELD / PROFESSIONALVIEW LAB